<ul id="x14oa"><meter id="x14oa"></meter></ul>

      <b id="x14oa"></b>

      1. 中文版 English
        TEL:
        +86-88781219
        Products
        Thin oil lubrication
        WGXYZA High Low Oil Station
         WGXYZA High low oil station is a oil lubrication deice combined of two parts ; high pressure part is 31.5MPa ,oil output 25L/min; and low pressure part is 0.4MPa ,oil output 16~125 L/min .This station holds units of filter, heater ,cooler etc. and function of safety , auto controller ,alarm etc .It is suitable for oil lubrication system of large scale equipment to lubricate hybrid bearing installed on the miller, rolling machine or electric the machine .Its working medium is industrial oil of N22~N320.According to the principle of dynamic and static pressure ,it uses the high system when the machine in starting , stopping or slow running ; uses the low system when running ordinary , to ensure the lubrication reliable on various speedy of large main machine ,and to prolong its life
        Example of order:
        A high-low oil station its high pressure is 31.5MPa, output 2.5L/min ,and low pressure is 0.4MPa, output 25L/min
        WGXYZ-25A high low oil station 
        Structure & Principle
        This station is consisted mainly of oil tanker (magnetic core mesh filter inner),low pressure pump device ,high pressure pump device ,twin barrel magnetic core mesh filter , heater ,cooler ,manual high pump , pipeline ,valve ,instrument panel ,electric controller etc . 
        Before starting main machine ,starts the low pump ,when its low filling pressure reached normal ,stars the high pump which suction port is connected to the pipeline of low pump. The high oil through high check valve flows to the static pressure bearing .When the high pressure reached a curtain value ,starts the main machine ,slow runs or stops. After main machine running normally then stops the high pump (exception the low running ),but the low pump must operate ordinary . The low pump suction oil from tanker ,then sends it pass check valve ,twin barrel mesh filter , cooler to the static pressure bearing too ,to maintain the main machine running ordinary .After stopped main machine ,if want filling oil by high or low pump timely ,can control by time relay to lubricate the point interrupt.
        The specific value of high or low pressure is controlled by high-low safety valve in the system.
        In the ordinary running of main machine , one low pump is working ,and another one is standing by . As the system pressure down at a value wanted , starts the ready pump , and then stops it while normal . If the pressure downing on still ,must sent an alarm ,and consider stopping the main machine.
        When the high plunger pump at fault , can fills oil by manual pump.
        Set the filter before the cooler , make the low viscidity oil passes the filter earlier , one filter at working , and another one at standing by , controlled by handle switch valve.
        Oil level higher or lower than a limit , are sent alarm by level signal , manual oil filling or stopping .
        Back oil passes the magnet mesh filter prepared in the tanker ,and can absorb the iron particulate at same time.
        Whole set of oil station is matched an instrument panel and an electric controller , to display operating data and to carry out at automatic , manual or alarm.
        A bimetallic electric contact thermometer installed on the tanker , when oil temp is too low sends a signal ,to open the heater by handle ,and stops automatically when reached an appointed temperature.

        A electric contact pressure type thermometer installed in the filling port , setting two limits of maximum and minimum temp needed ,to determine the cooler working or not.


        Appearance and dimensions:



        parameter/type
        WGXYZ WGXYZ WGXYZ WGXYZ WGXYZ WGXYZ
        16A 25A 40A 63A 100A 125A
        low system 
        pump type    LBZ-16 LBZ-25 LBZ-40 LBZ-63 LBZ-100 LBZ-125
         output L/min 16 25 40 63 100 125
        filling pressure MPa 0.4
         filling ℃ 40±3
        motor  type Y90S-4,V1 Y100L1-4,V1 Y112M-4,V1
         power 1.1 2.2 4
         velocity 1400 1400 1440
         tank m3 0.8 1.2 1.6
        high system 
         pump type     2.5MCY14-1B    
         output L/min     2.5    
        filling pressure MPa 31.5
        motor
         type Y112M-6 B35
         power 2.2
         velocity 940
         filter precision mm 0.08
         filter area m2 0.13 0.19 0.40
         cooling area m2 3 5 7
         consume of cooling water m3/h 1 1.5 3.6 5.7 9 11.25
         power of heater kW 3*4 3*4 6*4
         demission mm 1820*1130*1320 1880*1220*1650 /
        note the switch differential pressure of all fillter are 0.15MPa

        type DN1 DN2 DN3 ND4 L B H L1 B1 H1 L2 L3 L4
        WGXYZ-16,-25 10 25 50 25 1650 1230 1500 1330 1080 1000 1250 410 420
        WGXYZ-40,-63 25 32 65 32 1800 1430 1550 1480 1280 1050 1400 270 440

        L5 L6 L7 L8 B2 B3 B4 B5 B6 B7 H2 H3 H4 H5 H6 H7
        100 80 120 280 160 200 180 420 280 360 70 78 285 450 890 1132
        140 60 140 300 190 230 200 500 380 400 120 110 285 500 930 1182

        lwo pressure system
        pump type output L/min pressure MPa motor

        type

        power kW velocity rpm
        LBZ-25 25 0.4 Y90S-4,V1 1.1 1400

        high pressure system
        pump type output L/min pressure MPa motor

        type

        power kW velocity rpm
        2.5MCY14-1B 2.5 31.5 Y112M-6,B35 2.2 940

        filling
        temperature

        cooling system

        tanker
        vjolume
        m3
        filter
        area
        m2
        filter
        percision
        mm
        power of
        heater
        kW
        cooling
        area m2
        water
        temperature ℃
        pressure MPa water
        consume m3/h
        40±3 3 ≤30

        0.2≤0.4

        1.5 0.8 0.19 0.05 3*4

        1.pressure controller(2 each of high , low)

        2.pressure gage(1 each of high , low) 

        3.pressure gage switch 

        4.pressure interface of pump 

        5.pressure interface of filling 

        6.differential pressure interface of filter 

        7.duplex pressure gage 

        8.electric contact pressure thermometer 

        9.pressure interface of high pressure


        lwo pressure system
        output L/min pressure MPa motor

        type

        power kW velocity rpm
        63 0.4 Y132S-4,V1 5.5 1400

        high pressure system
        output L/min pressure MPa motor

        type

        power kW velocity rpm
        2.5 31.5 Y112M-6,B35 2.2 940

        filling
        temperature℃

        cooling system

        tanker
        vjolume
        m3
        filter
        area
        m2
        filter
        percision
        mm
        power of
        heater
        kW
        cooling
        area
        m2
        water
        temperature
        pressure MPa water
        consume
        m3/h
        40±3 3 ≤30

        0.2≤0.4

        1.5 0.8 0.19 0.05 3*4
        Inquiry

        Copyright ? Wenzhou Zhonghe Lubrication Equipment Manufacturing Co., Ltd. INC. ALL RIGHTS RESERVED.

        浙ICP備11048852號 Technical Support:lianke

        Sweep with WeChat

        Experience mobile website

        Online Consultation

        Working Day:9:30-21:00
        Weekend:10:00-17:00

        Online Consultation

        Please leave a message
        *

        Title

        *

        Name

        *

        Tel

        *

        E-mail

        *
        中文字幕人妻无码专区激情,亚洲免费人成视频,1024精品视频在线,超碰97人人做人人爱高清

        <ul id="x14oa"><meter id="x14oa"></meter></ul>
        
        
            <b id="x14oa"></b>